{"id":699,"date":"2010-03-08T16:27:11","date_gmt":"2010-03-08T15:27:11","guid":{"rendered":"http:\/\/ccievoice.ksiazek.be\/?p=699"},"modified":"2025-01-11T18:28:02","modified_gmt":"2025-01-11T17:28:02","slug":"cue-basic-integration-with-cme","status":"publish","type":"post","link":"https:\/\/collaboration.ksiazek.be\/?p=699","title":{"rendered":"CUE Basic Integration with CME"},"content":{"rendered":"<p>Here are all the steps to perform if you want to integrate the CUE with the CME<\/p>\n<blockquote>\n<ol>\n<li>Create a SIP dial peer pointing to the CUE Module<\/li>\n<li>Configure the MWI On\/Off extensions<\/li>\n<li>Configure the connectivity between CME and CUE Modules<\/li>\n<li>Perform CUE Configuration<\/li>\n<\/ol>\n<\/blockquote>\n<p>For the first step , your dial peer will look like<\/p>\n<blockquote><p><em>dial-peer voice 1000 voip<\/em><br \/>\n<em>destination-pattern 5555<\/em><br \/>\n<em>session protocol sipv2<\/em><br \/>\n<em>session target ipv4:172.17.1.1<\/em><br \/>\n<em>dtmf-relay sip-notify<\/em><br \/>\n<em>codec g711ulaw<\/em><br \/>\n<em>no vad<\/em><br \/>\n<em>!<\/em><\/p><\/blockquote>\n<p>The configurations of the MWI On\/Off must be generic as it must cover all numbers and it is generally implemented as a kind of prefix as the MWI must know which number must be turned on or off. So it adds the number after the extension the MWI shortcut.<\/p>\n<blockquote><p><em>ephone-dn 50<\/em><br \/>\n<em>number 5000&#8230;.<\/em><br \/>\n<em>mwi on<\/em><br \/>\n<em>!<\/em><br \/>\n<em>ephone-dn 60<\/em><br \/>\n<em>number 6000&#8230;.<\/em><br \/>\n<em>mwi off<\/em><\/p><\/blockquote>\n<p>Regarding the link configuration between the CUE and CME, you need to borrow the Ethernet interface where the CUE module resides (don&#8217;t forget that CME and CUE can be splitted). So everything under the service-engine ( this is the CUE module) will rely on the Ethernet interfaces:<\/p>\n<blockquote><p><em>interface Service-Engine 1\/0<\/em><br \/>\n<em>ip unnumbered FastEthernet 1\/0<\/em><br \/>\n<em>service-module ip address 172.17.1.1 255.255.255.0<\/em><br \/>\n<em>service-module ip default-gateway 172.17.1.254<\/em><br \/>\n<em>!<\/em><br \/>\n<em>ip route 172.17.1.1 255.255.255.255 Service-Engine1\/0<\/em><br \/>\n<em>!<\/em><\/p><\/blockquote>\n<p>In a multi-site implementations , you have then to configure a translation between your remote CME and the central CUE\/CME because we told before that CUE relies on SIP Protocol and the rest of your network is an H323 network , so you need to translate all H323 request to SIP. You can do it generally with the config:<\/p>\n<blockquote><p><em>!<\/em><br \/>\n<em>voice service voip<\/em><br \/>\n<em>allow-connections H323 to sip<\/em><\/p><\/blockquote>\n","protected":false},"excerpt":{"rendered":"<p>Here are all the steps to perform if you want to integrate the CUE with the CME Create a SIP dial peer pointing to the CUE Module Configure the MWI On\/Off extensions Configure the connectivity between CME and CUE Modules Perform CUE Configuration For the first step , your dial peer will look like dial-peer [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"categories":[47,13,28,30,62,1,68,33],"tags":[61,246,250,29,253,69],"class_list":["post-699","post","type-post","status-publish","format-standard","hentry","category-ccme","category-cuc","category-h323","category-ios","category-lab","category-non-classe","category-sip","category-written-theory","tag-ccie-voice-lab","tag-cme","tag-cue","tag-h323","tag-service-engine","tag-sip"],"_links":{"self":[{"href":"https:\/\/collaboration.ksiazek.be\/index.php?rest_route=\/wp\/v2\/posts\/699","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/collaboration.ksiazek.be\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/collaboration.ksiazek.be\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/collaboration.ksiazek.be\/index.php?rest_route=\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/collaboration.ksiazek.be\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=699"}],"version-history":[{"count":1,"href":"https:\/\/collaboration.ksiazek.be\/index.php?rest_route=\/wp\/v2\/posts\/699\/revisions"}],"predecessor-version":[{"id":4379,"href":"https:\/\/collaboration.ksiazek.be\/index.php?rest_route=\/wp\/v2\/posts\/699\/revisions\/4379"}],"wp:attachment":[{"href":"https:\/\/collaboration.ksiazek.be\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=699"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/collaboration.ksiazek.be\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=699"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/collaboration.ksiazek.be\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=699"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}